-
Válvulas solenóides normalmente fechado N.C. e normalmente aberto N.O. ode
-
válvulas solenóides indiretas ou servo-controladas ODE CEME PARKER AIGNEP
- Indirectly controlled solenoid valves normally closed nbr buna viton fkm ptfe teflon epdm
-
Indirectly controlled solenoid valves normally open nbr buna viton fkm ptfe teflon epdm
- 21WA3Z0B130, 21WA4Z0B130, 21WA3Z0V130, 21WA4Z0V130, 21WA3Z0E130, 21WA4Z0E130
- válvula solenóide de água normalmente aberta 12v 24v 48v 110v 220v nbr buna
- normally open water solenoid valve 12v 24v 48v 110v 220v nbr buna
- électrovanne d'eau normalement ouverte 12v 24v 48v 110v 220v nbr buna
- válvula solenoide de agua normalmente abierta 12v 24v 48v 110v 220v nbr buna
-
válvulas solenóides ODE CEME PARKER AIGNEP controle direto 2 ou 3 vias
-
válvulas solenóides de controle misto, pressão operacional mínima 0 bar
- ode pneumatic control valves, camozzi pneumatic solenoid valves
-
válvulas solenóides para lavagem de carros autoequip aquarama istobal ceccato
- válvula solenóide cera limpador de piso, desengordurante líquido alcalino
- válvulas de retenção de retenção 316 aço inoxidável 250 bar peek core
- válvulas de retenção válvula de retenção em latão ITAP EUROPA
- válvula de esfera em aço inoxidável 316 PTFE PN67
- brass ball valve water autoclave irrigation electropumps
-
21H7KV120, 21H8KV120, 4743K0V120, 21A2KV25, 21A2KV30, 4966K0Q120, 21WA4K0V130
- ode 21H7KV120 BDA08024DS 24V AC BDA08024CS 24V DC BDA08048AS 48V AC
- ode 21H7KV120 BDV08024DY 24V AC BDV08024CY 24V DC BDV08230AY 230V
- ode 21H8KV120 BDA08024DS 24V AC BDA08024CS 24V DC BDA08048AS 48V AC
- ode 21H8KV120 BDV08024DY 24V AC BDV08024CY 24V DC BDV08230AY 230V
- KIT DE MANUTENÇÃO DA VÁLVULA SOLENÓIDE ODE 4743K0V120 21H8KV120 21H7KV120
- DIAPHRAGM ODE R450916/V 4743K0V120 21H8KV120 21H7KV120 21H7KB120 21H8KB120 5116K0V120
- N.O. CARWASH 21HT3Z0V110, 21HT4Z0V160, 21HT5Z0V160,
- VÁLVULA SOLENÓIDE SEM BOBINA SÓ CORPO DA VÁLVULA ÍMÃ DE SOLENÓIDE
- válvulas solenóides de pistão indireto
- válvulas solenóides biestáveis latch impulse 6v 9v 12v 24v
- válvulas solenóides de atomização
- válvulas solenóides combustível de aviação diesel gasolina agrícola 12v 24v 110v 220v
- timer
-
válvulas solenóides para máquinas de café, new simonelli, spm, necta, space,
- 3-way solenoid valve ode 1/8 230v compatible Nuova Simonelli coffee machines
- ODE 3-WAY SOLENOID VALVE SPAZIALE COFFEE MACHINES CONTI BFC FIORENZATO
- 21JN1RRV20-XT LBV05024CU SOLENOID VALVE 1/8 SAECO SYNTIA INTUITA MINUTE
- 31A1AR15-VORV SOLENOID VALVE 3 WAYS COMPATIBLE DUCAL ACADEMY SPAZIO FAEMA
- 21JN1R0V23 SOLENOID VALVE 1/8 QUICK MILL SAN MARCO SPM SCALA JAZZ
- ODE 21JN1R0V12 LBA05230AS 230V 240V SOLENOID VALVES 1/8 POD COFFEE MACHINES
- válvulas solenóides de gás natural impulse 12v 24v 42v 48v 110v 220v atex
-
válvulas solenóides água quente fria ar comprimido gases inertes nitrogênio
- N.C. 21WA4K0B130, 21W3KB190, 21W4KB250, 21W5KB350, 21W6KB400, 21W7KB500
- N.O. 21WA4Z0B130, 21W3ZB190, 21W4ZB250, 21W5ZB350, 21W6ZB400, 21W7ZB500,
- 21HT3K0Y110, 21HT3K0Y110-S, 21HT4K0Y160, 21HT5K0Y160, 21HT6K0Y250,
-
21H7KB120, 21H8KB120, 21H9KB190, 21WA3R0B130, 21WA4R0B130,
- idroenergiaitalia ode 21WA4R0B130_LBA05024AS 24v ac
- idroenergiaitalia ode 21WA4R0B130_LBA05230AS 230v 240v ac
- idroenergiaitalia ode 21WA4R0B130_LBA05024CS 24v dc
- idroenergiaitalia ode 21WA4R0B130_LBA05012CS 12v dc
- idroenergiaitalia ode 21WA4R0B130_LBA05110AS 110v ac
- idroenergiaitalia ode 21WA4R0B130_LBA05012AS 12v ac
-
válvulas solenóides em aço inoxidável Aisi 316 juntas em viton ou teflon
- 21IH2K1V110, 21IH3K1V150, 21IH4K1V160, 21IH5K1V200, 21IH6K1V250, 21IH7K1V350, 21IH8K1V400,
- 21X2KV120, 21X3KV190, 21X4KV250, 21X2KT120, 21X3KT190, 21X4K1T250,
- 21JL1R1V12, 21JL1R1V23, 31JL1XP1V12, 31JL1XP1V12-S, 31JL1XP1V12-PB, 21L2K1V15-XC,
- 21L1K1T25, 21L1K1T30, 21L1K1T40, 21L2K1T25, 21L2K1T30, 21L2K1T40, 21L2K1T55,
- 21L1K1V25, 21L1K1V30, 21L1K1V40, 21L2K1V25, 21L2K1V30, 21L2K1V40, 21L2K1V55,
- 21L1K1E25, 21L1K1E30, 21L1K1E40, 21L2K1E25, 21L2K1E30, 21L2K1E40, 21L2K1E55,
- 31L1A1T30-R, 31L2A4T30, 31L2A1V30, 31L2F0V15-U, 21L1K1T15-XC,
- válvula asséptica, válvulas assépticas operadas pneumaticamente
- válvulas solenóides para vapor e água quente 140° impulse 12v 24v 42v 48v 110v 220v atex
- válvulas solenóides vapor água quente superaquecida a 180 °
- válvulas solenóides de água para piscinas, destiladas, desmineralizadas
- válvulas solenóides butano, hexano, propano, metano, etano, heptano,
- válvulas solenóides piloto para atuadores pneumáticos
- válvulas solenóides sistemas de aquecimento lareira térmica
- válvulas solenóides secadoras dreno de condensado de ar comprimido
- válvulas solenóides tinta, corantes, tintas, solventes para vernizes
- remoção de ervas daninhas de válvulas solenóides, atomizador, pulverização, desinfestação,
- válvulas solenóides electrolux bosh whirpool aeg beko elbi zanussi bitron
- válvulas solenóides chuveiros fichas máquinas de lavar roupa fichas piscinas
- válvulas solenóides de separação total para equipamentos médicos
- válvulas solenóides equipamentos equipamentos assistência dentistas
- válvulas solenóides para irrigação agrícola, jardinagem, estufas,
- válvulas solenóides desengraxadas para gases técnicos OX de oxigênio industrial
- válvulas solenóides para fertirrigação. fertilizantes, fertilizantes líquidos
- válvulas solenóides de osmose reversa, água osmótica,
- válvula solenóide 12v dc corrente contínua alimentada por bateria
- Válvulas solenóides ODE certificadas pela NSF para fluidos alimentares
- Válvula solenóide de gás refrigerante R 134a, R 404a etc.
- válvulas solenóides para compressores de ar, embalagem, lavagem, maquinário industrial,
- válvulas solenóides para limpeza e desinfecção de hospitais industriais civis
- válvulas solenóides descarga vapor de água co2 lavagem a seco
- válvulas de diafragma para a indústria de alimentos cosméticos médicos
- válvulas solenóides para fontes automação jogos aquáticos cachoeiras laminares
- válvulas solenóides geradores bombas motoras autoclave de combate a incêndio
- válvulas solenóides de alta pressão ar comprimido co2 água de combate a incêndios
- válvulas solenóides para fluidização no processo industrial
- válvula solenóide para água 7321 B PARKER n.c. normalmente fechado
-
válvulas solenóides indiretas ou servo-controladas ODE CEME PARKER AIGNEP
-
peças sobressalentes pistões membranas núcleos móveis mangas bobinas solenóides conectores válvulas solenóides ode
-
Bobinas solenóides ímãs eletroímãs ode camozzi parker ceme pneumax aignep metalwork
- BDA08012AS, BDA08012CS, BDA08024CS, BDA08024DS, BDA08110DS, BDA08223DS
- BDA08048AS, BDA08048CS, BDA08042AS,BDA08230CS, BDA08110CS, BDA08380DS
- BDV08230AY, BDV08024DY, BDV08024CY, BDV08110AY, BDV08012CY
- BDV08230A3, BDV08024D3, BDV08024C3, BDV08110A3, BDV08012C3, ATEX EX NA
- LBA05230AS, LBA05024AS, LBA05024CS, LBA05012CS, LBA05110AS
- BDA08036CS, BDA08042AS, BSA08223DS, BDP08223DS,
- LBV05024AV, LBV05024CY, LBV05110AY, LBV05230AY, LBV08024HU, LBV05024BW,
- LBA2X012CS, LBA2X024AS, LBA2X024CS, LBA2X110AS, LBA2X230AS,
- LBV05024A3, LBV05024B3, LBV0524C3, LBV05110A3, LBV05230A3,
- BDA1X004LS, BDA2X006LS, BDA05006LS, BDA05009LS, BDA1X0063S, BDA2X009LS,
- BDA05012LS, BDA1X009LS, BDA2X012LS, BDA10024LS, BDA1X012LS, BDA05024LS,
- BDA08115BS, BDA08200DS, BDA08240AS, BDV08110BW, UDV12230AY, UDV12230DW,
- UDA12024AS, UDA12024CS, UDA12110DS, UDA12230AS, UDV12024CY, UDV12112DW,
- GDH14024CS, GDH14024DS, GDH14110DS, GDH14223DS, GDV14024CY, GDV14024DY,
- GDV14110AY, GDV14230AY, GDV14024C3, GDV14024D3, GDV14110A3, GDV14230A3,
- GDH14018CS, GDH14077CS, GDA14012CS, ICA12024ES, ICA12024HS, ICA12230ES,
- bobinas solenóides ode compatíveis para válvulas solenóides watts
- PNEUMAX MB4, MB5, MB9, MB56, MB57, MB58, 22mm x 10mm
- CAMOZZI, U77, U7H, U7K, U7J,
- coil solenoid magnet electromagnet parker 12v 24v 110v 220v 240v
- PNEUMAX MF4, MF5, MF56, MF57, MF58, 12VDC, 24VDC, 24VAC, 110VAC, 220V,
- Kit de manutenção reparo de válvula solenóide ODE CEME PARKER AIGNEP
- montagem do núcleo móvel, pistões, molas ode
- Máquina de café com bomba de água Mokona Bialetti Saeco Gaggia Philips
- válvulas ou bobinas solenóides camozzi
- complete armature tube
-
membranas NBR FKM PTFE PBT para válvulas solenóides ode
- R452186/B ode 21wa3r0b130, 21wa4r0b130, 21wa3k0b130, 21wa4k0b130,
- R452186/B-21wa3z0b130-21wa4z0b130-21wn3r0b130-21wn4r0b130-21WN3z0b130-21wn4z0b130
- R450431/B 21W3KB190-21W4KB250-21WN5KB190-21WN6KB250-21W3ZB190-21W4ZB250-21WN5ZB190-21WN6ZB250
- R450466/B-21W5KB350-21W6KB400-21W5ZB350-21W6ZB400-21WN7KB350-21WN8KB400-21WN7ZB350-21WN8ZB400
- R450432/B-21w7kb500-21w7zb500-21wn9kb500-21WN9ZB500
- R452186/V-21wa3r0v130-21wa4r0v130-21wa3k0v130-21wa4k0v130-21wn3k0v130-21wn4k0v130
- R452186/V-21wa3z0v130-21wa4z0v130-21wn3r0v130-21wn4r0v130-21WN3z0v130-21wn4z0v130
- R450431/V-21W3KV190-21W4KV250-21WN5KV190-21WN6KV250-21W3ZV190-21W4ZV250-21WN5ZV190-21WN6ZV250
- R450466/V-21W5KV350-21W6KV400-21W5ZV350-21W6ZV400-21WN7KV350-21WN8KV400-21WN7ZV350-21WN8ZV400
- R450432/V-21w7kv500-21w7zv500-21wn9kv500-21WN9Zv500,
- R452186/E-21wa3z0e130-21wa4z0e130-21wn3r0e130-21wn4r0e130-21WN3z0e130-21wn4z0e130
- R452186/E-21wa3r0e130-21wa4r0e130-21wa3k0e130-21wa4k0e130-21wn3k0e130-21wn4k0e130
- R450431/E-21W3KE190-21W4KE250-21WN5KE190-21WN6KE250-21W3ZE190-21W4ZE250-21WN5ZE190-21WN6ZE250
- R450466/E-21W5KE350-21W6KE400-21W5ZE350-21W6ZE400-21WN7KE350-21WN8KE400-21WN7ZE350-21WN8ZE400
- R450432/E-21w7ke500-21w7ze500-21wn9ke500-21WN9Ze500
- R451220/V DIAPHRAGM VITON FKM SOLENOID VALVE ODE 21H9KV180 21EN5KV180
- conectores IP65, IP67, atex, ul, csa, quadrado, retangular, para válvulas solenóides ode
- Transdutor de pressão certificado pela UL CSA ou com conector de cabeçalho EN175301-803
-
Bobinas solenóides ímãs eletroímãs ode camozzi parker ceme pneumax aignep metalwork
-
pneumatic solenoid valves pneumatic pneumatic cylinders camozzi pneumax
-
válvulas solenóides para máquinas, máquinas, sistemas para agricultura
- válvulas solenóides para óleo do motor, óleo lubrificante, óleo mineral,
- válvulas solenóides para bombas elétricas submersíveis, autoclaves, tanques
- válvulas solenóides com membrana ou núcleo móvel de EPDM
- Válvulas solenóides piloto de 3 vias para válvulas hidráulicas de irrigação
- válvula solenóide de co2 de baixo consumo para aquário 220v
-
trocadores de placas, acessórios de bombas, separadores hidráulicos, coletores de aquecimento, medidores, circuladores,
-
Unidades de aquecimento, coelte, construções eletrônicas de telesine.
- UNIDADE DE CONTROLE ELETRÔNICO TERMO LAREIRA ÁGUA COELTOP RLX 3 MÓDULOS EURO 40,00
- MULTI-ZONE ELECTRONIC CONTROL UNIT FOR HEATING SYSTEM ZC04 4 ZONE
- CALEFFI FLOW SWITCH NORMALLY OPEN 1/2 315400 VAILLANT 151047 BOILER
- Anti-condensation valve for solid fuel heat generators
- SOLAR THERMOSTATIC MIXER KIT FAR SOLENOID VALVE ODE N.O. And N.C 1/2
- CIRCULATOR PUMP HEATING SYSTEM FIREPLACE HEAT STOVE HEATER
- válvulas solenóides para irrigação agrícola, jardins, estufas, hidroponia
- Coletores de aquecimento de refrigeração de ar condicionado
- Circuladores de bomba de aquecimento e resfriamento
- Medidores de Madalena hidroconta para água fria, água quente, lançador de impulsos
- Acessórios em latão
- trocadores de calor Pacetti
- trocadores de calor zilmet
- Separadores hidráulicos - separador hidráulico - compensador hidráulico
- Válvula anti-condensação para geradores de calor a combustível sólido
- vaso de expansão
- válvula motorizada de zona esférica atuador 24v 230v pneumático
- acessórios e componentes para bombas elétricas
- álvula de esfera, válvulas de retenção, válvulas clapet, válvulas de segurança,
- acessórios, acessórios de aço inoxidável 316, ferro fundido maleável, cobre, bronze
- válvula solenóide do sistema de aquecimento n.c. e n.o.
- válvula solenóide enchimento automático do trocador de calor da caldeira
- substituição de motores submersíveis nema anexo para bombas elétricas submersíveis
- válvulas solenóides sistemas solares térmicos produção de água quente sanitária
- ermostatos, interruptores de pressão, interruptores de fluxo, redutores de pressão, cronômetro
- Thermostatic mixer for solar systems producing domestic hot water
-
Unidades de aquecimento, coelte, construções eletrônicas de telesine.
-
debem bombas centrífugas, debem bombas pneumáticas, bombas para a indústria
-
bombas para a indústria química, bombas químicas, bomba química
- Bombas pneumáticas de diafragma duplo debem
- magnetic drive centrifugal pumps series DM, KM, debem
- drums transfer pumps debem
- Pulsation dampeners debem
- vertical centrifugal pumps IM debem
- Agitator and peristaltic pump debem
- horizontal pumps with mechanical seal MB debem
- Bombas pneumáticas de diafragma duplo debem sanitária e alimentar
-
bombas para a indústria química, bombas químicas, bomba química
- 316 acessórios de aço inoxidável, 316 stainless steel fittings
Sign In
Accedi con account social
- Fai il login con Facebook
- Fai il login con Google
- Fai il login con PayPal
- Indirectly controlled solenoid valves normally open nbr buna viton fkm ptfe teflon epdm
-
- 21WA3Z0B130, 21WA4Z0B130, 21WA3Z0V130, 21WA4Z0V130, 21WA3Z0E130, 21WA4Z0E130
- válvula solenóide de água normalmente aberta 12v 24v 48v 110v 220v nbr buna
- normally open water solenoid valve 12v 24v 48v 110v 220v nbr buna
- électrovanne d'eau normalement ouverte 12v 24v 48v 110v 220v nbr buna
- válvula solenoide de agua normalmente abierta 12v 24v 48v 110v 220v nbr buna
Indirectly controlled solenoid valves normally open nbr buna viton fkm ptfe teflon epdm
2-way solenoid valves normally open servo-controlled
Main components: body with main orifice, cover with pilot orifice, diaphragm (or piston) assembly, quill + mobile core + gasket + gasket assembly (kit normally open), coil. operation: the normally open 2-way solenoid valves servo-controlled have an inlet fitting and a usage fitting. as regards the displacement of the membrane, identical to that of the normally closed 2-way solenoid valves servo-controlled, but instead of the normally closed kit, a normally open kit is mounted which opens and closes the pilot orifice. In this case, therefore with the coil powered, the pilot orifice will be closed and therefore the membrane in a position to close the main orifice, while with the coil not powered, the pilot orifice is open causing the opening of the main orifice. there will be a minimum difference in pressure between the supply fitting and the one used to guarantee correct operation of the solenoid valve itself. However, an excessive pressure difference between the supply and the use, as on the normally open 2-way solenoid valves with direct control, causes an increase in the force required to open the pilot orifice, so if this pressure difference it is higher than the maximum value for which the solenoid valve was designed, the latter may not reopen even when the coil is not powered. For the correct operation of the solenoid valve and to avoid the rapid deterioration of the membrane, it is desirable that, when starting to close the valve, the flow rate value does not exceed Kv, i.e. the guaranteed flow rate with loss of load through the solenoid valve equal to 1 bar. For this reason, if the supply pressure with the valve open is higher than 1 bar, the use of the free-mouth valve is not recommended, i.e. without a suitable throttle on the discharge port which brings the pressure drop on the solenoid valve back to the value of 1 bar. In addition, particular attention must be paid in the design of the hydraulic circuit to the problem of water hammers, which can cause overpressures such as to tear the membrane or damage other parts of the solenoid valve.
There are 20 products.